Model |
SP1101X |
Category |
Cat.6 |
Cable Type |
SF/UTP |
Wiring Standard |
ANSI/TIA-568-C.2 & UL444 & ISO/IEC 11801 |
Length (M) |
305 |
Certification |
UL |
Conductor |
Size: 23Awg
Construction: Solid Bare Copper |
Insulation |
Avg. Thick.: 0.255mm
Min. Thick.: 0.245 mm
Diameter: 1.06 ± 0.02 mm
Material: HDPE(High Density Polyethylene)
Color Codes:
Blue × White/Blue Stripe
Orange × White/Orange Stripe
Green × White/Green Stripe
Brown × White/Brown Stripe
Unaged Tensile Strength: 2400 Psi Min. (1.69 Kg/M M2)
Unaged Elongation: 300% Min.
Aged Tensile Strength: Unaged Min. 75% (100°C x 48Hrs)
Aged Elongation: Unaged Min. 75% (100°C x 48Hrs) |
Shielded |
Pair Stranded: 2 Cores Stranded
Filler(Slot): Hdpe Isolator Separator
Assembly Stranded: 4 Pair Stranded
SHIELDED: AL-MYLAR TAPE
SHIELDED: BRAID
COVERAGE RATE: 41% |
Jacketed |
Avg. Thick.: 0.50 mm
Min. Thick.: 0.47mm
Diameter: 7.40 ± 0.2 mm
Material: PVC
Color: Gray or Other Color
Unaged Tensile Strength: 2000 Psi Min. (1.41 Kg/M M2)
Unaged Elongation: 100% Min.
Aged Tensile Strength: Unaged Min. 85% (100°C x 240Hrs)
Aged Elongation: Unaged Min. 50% (100°C x 240Hrs) |
Item |
23Awg × 4P |
Rating Temp Voltage |
75°C 300V |
Conductor Resistance |
9.38 OHM/100M/20°C Max. |
Mutual Capacitance |
56 pF/M Max. |
Dielectric Strength |
AC 1.5 KV/2 Sec. |
Spark Test |
2.5 KV |
Insulation Shrinkback |
150m/m, 121°C ± 1°C × 1HR≦9.5m/m |
Cold Bend Test |
-20°C × 4HRS No.Crack |
Flame Retardant Test |
PVC |
Dc Resistance Unbalance |
5% Max. |
Pair-To-Ground Capacitance Unbalance |
330 pF/100m Max. |
Propagation Delay |
250 MHz 536.3nS/100m Max. |
Delay Skew |
1 ~ 250 MHz 45nS/100m Max. |